Shielded CAT6 Cable Bulk - Orange STP Spool

Vertical Cable

$219.89
(1 review) Write a Review
SKU:
189-008
UPC:
845643005063
Weight:
43.00 LBS
Bulk Pricing:
Buy in bulk and save
Adding to cart… The item has been added

Orange Shielded CAT6 Cable Bulk, Solid 1,000 ft. On Spool

Color: Orange
Category: Cat6
Length: 1,000 foot
Manufacturer SKU: 062-507/S/OR

F/UTP or Foiled Unshielded Twisted Pair CAT6 cable is probably more cable than the average home user needs but in the workplace it may be the ideal (or even the only) solution available. The foil shielding protects your data as it travels through the four twisted pairs of 23 gauge solid copper wires by wrapping it in a thin metal sleeve thus keeping electrical interference from things like fluorescent lights and electrical lines found in a drop ceiling or inside walls at a minimum. Cables For Less CAT6 Shielded Cable comes in a variety of colors.

This is a 1,000 foot roll of shielded CAT6 cable that comes on a WOODEN SPOOL providing you with of high quality, shielded, 4-pair, solid, 550 MHz Cat6 Cable, ready for termination and routing. Simply spool off the length required for your installation and terminate at your leisure. These spools are a great aid in large scale network installations and other long distance cable runs. And like all of our bulk networking CAT5 or CAT6 Cables, these are constructed with only high-quality components that can be counted on for high performance! So let us help you make the connections you need, and help us save the world... from high priced cables. 

F/UTP cable, short for foiled unshielded twisted pair, is typically used to reduce electrical interference. Because most cable that is ran through a building is not crossing over fluorescent lights or draped over electrical wires the shielded cable is not commonly used and the plenum version of this cable which is intended to be used in plenum spaces (areas such as heating ducts etc. which allow fire and smoke to travel quickly) can be quite expensive since it is coated with a jacket that reduces the levels of toxicity in the smoke and is less common. 
Of course check with the proper agencies as well as consulting your county, city, state or federal guidelines before assuming anything in regard to what cable is the right cable for your application.

Still have questions? Check out this helpful link we've put together...
www.cablesforless.com/network-cables-explained
Or simply call us up at 800-273-9556!

 

If you don’t quite need a whole box or feel like building these yourself then you may be interested to know that we can custom build a wide variety of patch cables on demand. If you’re already setup with the tools you’ll need as well as endsjacks and the Ethernet Cable DIY knowledge then it’s not a problem. If you’d rather just have us do it then we have a set of easy to use custom length ethernet cable calculators you can use to quickly price out what you need and we can build them for you!

 

Details:

  • 1,000 foot of bulk cable on a WOODEN SPOOL
  • 550 MHz, shielded, solid Cat6 cable
  • Shielded Twisted Pair to reduce crosstalk and interference
  • 4 pair, 23 AWG
  • Solid Copper Conductors
  • 1000 foot length, Un-terminated
  • Exceeds TIA/EIA 568-C.2, ISO/IEC 11801
  • Gigabit Ethernet Ready
  • Riser Rated PVC Jacket, CMR
  • RoHS compliant / ETL verified
  • Incremental markings every 2 feet
  • Easily Identified Color-Striped Pairs 

While terminating Category 6 twisted pair cables be sure the natural twist of each pair is carried through as close as practical to the point of mechanical termination. TIA/EIA 568-B.2 requires no more than 0.5 inch (13mm) untwisted for Category 5E as it will effect performance at high bit rates. Cabling should be secured and placed in a manner which prevents kinking and tight cinching. Do not excessively bend the cable greater than four times the cable diameter. Cabling should not be subject to greater than 25 pounds of pulling tension (110N).


For snag resistant operation this spool should be handled properly, pull the cable while the spool is secured on an adequate cable caddie or other dispenser in the upright position only. For ideal conditions this cable must be stored at or above 32 degrees fahrenheit 48 hours prior to installation.